Non-conductive coatings or platings put over ferrous bases are measured using our DMQ QC3 DLF dry coating thickness gauge. Paint, varnish, laquer, nickel, zinc, chromium, and many more materials may be measured rapidly and reliably. This variant has a Data Logger that can store up to 5000 readings and send them to a PC via USB using the DMQ DataCenter software.
Specification
Features
Catalog
Specifications
Details
Measurement method
Ferrous Base Eddy Current Range: 0 - 1500µm 0 - 60Mils Resolution: Up to 99.9µm, 0.1µm Up to 4.99Mil, 0.01Mil Above 100µm, 1µm Above 5Mil, 0.1Mil
Power Supply
2 x AA 1.5v Alkaline 2 x AA 1.2v Ni-MH Rechargeable Easy slide battery compartment cover
Connection
USB to connect to a PC or RS232 (optional cable) Type Lemo "0B" connector for probe
Alarm
Low & High, user defined Alarm types Visible: Flashing backlight and irregular digits Audible: Intermitent beep